Austin · current code · September 2026
What a small lot yields with one stair instead of two
A parametric comparison of the two-stair rule against the point access block, on a lot too narrow for a double-loaded corridor. Change the numbers; the plans and the math follow.
Inputs
street frontage
front to rear
each side
scheme A only
Austin cap: 5
Austin cap: 4
compatibility trigger
The two floor plates, same lot
A · Two stairs, single-loaded
What the old rule actually allows on a narrow lot
B · Point access block
One protected stair, units on all sides of a central core
What the difference is worth
| Per floor | A · two stairs | B · point access | Difference |
|---|
Code checks - the numbers behind the claims
Read this before using any of it
- The real argument is not "one stair is better than two." It is that on a lot this narrow a double-loaded corridor does not fit at all - the building is not deep enough to put units on both sides of a hall. So the honest comparison is against a single-loaded plate, which spends corridor on one row of units and still pays for two stairs. That is the plate being beaten here, and it is the plate that actually gets built.
- Two exposures is the part that does not show up in a spreadsheet. Every unit in scheme B spans the full building depth, so it has windows front and back: cross-ventilation, light from two directions, and a corner in most cases. In scheme A every unit faces one way. The efficiency gain is the argument to a developer; the two exposures are the argument to a renter - and they are what makes it a better apartment rather than only a cheaper one. Be precise about which two sides deliver this. At a tight side setback, fire-separation rules cap side-wall glazing well below a full window wall (see Code checks below) - the real dual-aspect benefit is almost always front and rear, not the two narrow sides.
- Fire response was the objection raised at Council, and it is not a bad-faith one. Know the sprinkler specification, the stairwell protection rating, and the travel-distance limit cold before presenting this anywhere. It will be the first question, and having a real answer is the difference between a study and an opinion.
- The circulation allowance in scheme B is a simplification. A real point access block
still needs a small elevator lobby and a landing at each level; here that is folded into the
core figure. A real plan will land a few points below the number this page produces -
which is fine, because it is still far above scheme A.